What is a transport noise corridor? Queensland's rules for building homes near busy roads and railways

A transport noise corridor is a strip of land beside a busy Queensland road or a railway where new homes must be built to keep road traffic or train noise out. Each part of the corridor has a noise category from 0 to 4, and the Queensland Development Code (QDC) Mandatory Part (MP) 4.4 sets how much sound insulation needs to be provided by the windows, walls, roof, floor and doors for homes in each category.

Where the rules come from

Corridors are designated under Chapter 8B of Queensland's Building Act 1975. The building rules that apply inside them are in Queensland Development Code MP 4.4 Buildings in a transport noise corridor. The current version is 1.1, dated 17 August 2015, and the code has applied to residential buildings approved since 1 September 2010. It's free to download from Business Queensland.

"MP" stands for mandatory part. Where QDC MP 4.4 applies, the building certifier has to be satisfied the design meets it before approving the building work.

Which roads and railways have corridors

Being near a busy road doesn't necessarily mean the site is in a transport noise corridor. Only a designated road or railway counts, and only inside the mapped area.

The state corridors are mapped on the Queensland Government's State Planning Policy Interactive Mapping System (SPP IMS), which opens from its planning mapping page. The layers are under Information Purposes, then Transport Infrastructure.

The State Planning Policy Interactive Mapping System showing Brisbane around the Gateway Motorway river crossing. The layer list has the mandatory state-controlled road and railway noise corridor layers ticked. Road corridors are shaded yellow to dark red along the motorway, and rail corridors purple.
The state mapping around the Gateway Motorway in Brisbane, with the mandatory state road and railway layers ticked. Road corridors show in yellow to dark red and rail corridors in purple, with the darker bands nearest the road or line. Source: State Planning Policy Interactive Mapping System, © State of Queensland.

Where to find the council maps

The state map doesn't show corridors on council roads. In Brisbane, Logan and Redland, check the council's planning scheme map as well:

QuietPath free check for a site on Jacaranda Avenue, Logan Central: QDC MP 4.4 noise category 2 from a Logan City Council road and category 1 from the railway, with both corridors shaded on the map.
The free check on Jacaranda Avenue, Logan Central. The site is in category 2 from a Logan council road, which the state mapping doesn't show, and category 1 from the railway. The higher category applies.

These council overlays also repeat the state road and rail corridors. Where the council map and the state map give different categories, the higher one applies.

The noise categories

The category is set by the noise level 1 m in front of the building's facade. For roads the measure is LA10,18h, the level exceeded for 10% of the time, averaged over the 18 hours from 6 am to midnight. For railways it's the maximum level as trains pass. Each category is a 5 dB band:

Noise categories, from QDC MP 4.4 Schedule 3 Table 1, with the minimum transport noise reduction for habitable rooms from Schedule 1.
CategoryRoad, LA10,18hRail, single event maximumMinimum noise reduction
473 dB(A) or more85 dB(A) or more40 dB(A)
368 to 72 dB(A)80 to 84 dB(A)35 dB(A)
263 to 67 dB(A)75 to 79 dB(A)30 dB(A)
158 to 62 dB(A)70 to 74 dB(A)25 dB(A)
057 dB(A) or less69 dB(A) or lessNo requirement

Category 0 is inside the corridor but quiet enough that nothing extra is required. Where a site is in more than one corridor, or designations disagree, the higher category applies. Where a building sits across two categories, each applies to the part of the building inside it.

What each category requires

MP 4.4 doesn't set an indoor noise level. It sets a minimum sound insulation rating, Rw, for each part of the external envelope of every habitable room (Schedule 1):

Minimum Rw for the external envelope of habitable rooms, from QDC MP 4.4 Schedule 1.
CategoryGlazing, room total over 1.8 m²Glazing, 1.8 m² or lessExternal wallsRoofFloorsEntry doors
4434352455135
3383547414533
2353241384533
127243535None28

Rw is a laboratory rating of how much sound a building element attenuates. A higher number means more sound insulation.

The glazing rating depends on the total area of glass in the room, including glazed doors. A room with more than 1.8 m² of glass needs the higher rating in categories 1 to 3.

Acceptable forms of construction

Schedule 2 lists constructions that are accepted as meeting each rating, so a design that uses them needs no test report. Some examples:

A construction that isn't in Schedule 2 can still be used if it has been tested to the required Rw. That matters most for lightweight clad walls at category 2 and above, where Schedule 2 offers only masonry and concrete.

Which buildings and rooms

QDC MP 4.4 applies to Class 1, 2, 3 and 4 buildings: houses, townhouses, secondary dwellings, units and apartments, boarding houses and short-term accommodation, and a dwelling attached to another kind of building. Relocated buildings are excluded. Business Queensland's guidance is that a major renovation, such as an alteration or addition, must comply for the part of the building it covers. Ask your certifier how they'll apply that to your project.

Within the building the requirements apply to habitable rooms: bedrooms, living and dining rooms, studies and kitchens. Bathrooms, laundries, toilets, hallways, walk-in robes and garages aren't habitable rooms.

Mapped category or a noise assessment

There are two ways to get the category.

The mapping is drawn for the land, before the building exists, and gives every storey the same category. A site-specific noise assessment models the building itself, so rooms on the far side of the house, shielded by the house, often come out one or more categories lower than the map shows. If there are solid fences or noise barriers as part of the development, the site-specific noise assessment will also consider how these reduce the category for each room.

What QDC MP 4.4 doesn't cover

The noise reductions in Schedule 1 assume the windows and doors are closed, so it's worth planning how those rooms will be ventilated and cooled with the windows shut.

The mapping changes

TMR updates the corridor mapping from time to time, and in mid-2026 it consulted on a remodel of the state-controlled road corridors. Check the current mapping when you apply for building approval, not the mapping from when you bought the land.

Sources

  • Queensland Government, Queensland Development Code MP 4.4 Buildings in a transport noise corridor, version 1.1, 17 August 2015, Schedules 1 to 3. Available from Business Queensland.
  • Business Queensland, Transport noise corridors.
  • Building Act 1975 (Qld), Chapter 8B.
  • Department of Transport and Main Roads, Transport Noise Management Code of Practice, Volume 1: Road Traffic Noise, 2013, chapter 8.
  • Queensland Government, Building and Plumbing Newsflash 499 (Logan), 566 (Redland) and 639 (2026 consultation on state-controlled road corridors).