What is a transport noise corridor? Queensland's rules for building homes near busy roads and railways
A transport noise corridor is a strip of land beside a busy Queensland road or a railway where new homes must be built to keep road traffic or train noise out. Each part of the corridor has a noise category from 0 to 4, and the Queensland Development Code (QDC) Mandatory Part (MP) 4.4 sets how much sound insulation needs to be provided by the windows, walls, roof, floor and doors for homes in each category.
Where the rules come from
Corridors are designated under Chapter 8B of Queensland's Building Act 1975. The building rules that apply inside them are in Queensland Development Code MP 4.4 Buildings in a transport noise corridor. The current version is 1.1, dated 17 August 2015, and the code has applied to residential buildings approved since 1 September 2010. It's free to download from Business Queensland.
"MP" stands for mandatory part. Where QDC MP 4.4 applies, the building certifier has to be satisfied the design meets it before approving the building work.
Which roads and railways have corridors
- State-controlled roads. The Department of Transport and Main Roads (TMR) maps the corridors. Each is split into a mandatory area, where MP 4.4 must be met, and a voluntary area, where the owner can choose to build to it.
- Railways. Rail corridors are all mandatory.
- Council roads. A council can designate its own roads. Logan (2012) and Redland (2019) have, and Brisbane's City Plan 2014 maps noise categories along council roads too. The state mapping doesn't show council roads, so check the council's planning scheme mapping as well.
Being near a busy road doesn't necessarily mean the site is in a transport noise corridor. Only a designated road or railway counts, and only inside the mapped area.
The state corridors are mapped on the Queensland Government's State Planning Policy Interactive Mapping System (SPP IMS), which opens from its planning mapping page. The layers are under Information Purposes, then Transport Infrastructure.
Where to find the council maps
The state map doesn't show corridors on council roads. In Brisbane, Logan and Redland, check the council's planning scheme map as well:
- Brisbane. The Transport noise corridor overlay in City Plan 2014 (overlay maps OM-020.3 to OM-020.5). Search the address in City Plan online, from the council's City Plan maps page.
- Logan. The Transport noise corridors overlay in the Logan Planning Scheme 2015. Search the address in the council's PD Hub, click the property and choose Overlays.
- Redland. The Transport Noise Corridor Overlay in Redland City Plan. Open Red-e-map from the council's Redland City Plan page.
These council overlays also repeat the state road and rail corridors. Where the council map and the state map give different categories, the higher one applies.
The noise categories
The category is set by the noise level 1 m in front of the building's facade. For roads the measure is LA10,18h, the level exceeded for 10% of the time, averaged over the 18 hours from 6 am to midnight. For railways it's the maximum level as trains pass. Each category is a 5 dB band:
| Category | Road, LA10,18h | Rail, single event maximum | Minimum noise reduction |
|---|---|---|---|
| 4 | 73 dB(A) or more | 85 dB(A) or more | 40 dB(A) |
| 3 | 68 to 72 dB(A) | 80 to 84 dB(A) | 35 dB(A) |
| 2 | 63 to 67 dB(A) | 75 to 79 dB(A) | 30 dB(A) |
| 1 | 58 to 62 dB(A) | 70 to 74 dB(A) | 25 dB(A) |
| 0 | 57 dB(A) or less | 69 dB(A) or less | No requirement |
Category 0 is inside the corridor but quiet enough that nothing extra is required. Where a site is in more than one corridor, or designations disagree, the higher category applies. Where a building sits across two categories, each applies to the part of the building inside it.
What each category requires
MP 4.4 doesn't set an indoor noise level. It sets a minimum sound insulation rating, Rw, for each part of the external envelope of every habitable room (Schedule 1):
| Category | Glazing, room total over 1.8 m² | Glazing, 1.8 m² or less | External walls | Roof | Floors | Entry doors |
|---|---|---|---|---|---|---|
| 4 | 43 | 43 | 52 | 45 | 51 | 35 |
| 3 | 38 | 35 | 47 | 41 | 45 | 33 |
| 2 | 35 | 32 | 41 | 38 | 45 | 33 |
| 1 | 27 | 24 | 35 | 35 | None | 28 |
Rw is a laboratory rating of how much sound a building element attenuates. A higher number means more sound insulation.
The glazing rating depends on the total area of glass in the room, including glazed doors. A room with more than 1.8 m² of glass needs the higher rating in categories 1 to 3.
Acceptable forms of construction
Schedule 2 lists constructions that are accepted as meeting each rating, so a design that uses them needs no test report. Some examples:
- Glazing. Rw 27 is 4 mm glass with acoustically rated seals around the full perimeter. Rw 35 is 10.38 mm laminated glass with the same seals. Rw 43, at category 4, is double glazing with two panes at least 5 mm thick and an air gap of at least 100 mm.
- Walls. At category 1 (Rw 35) a framed wall is accepted: 6 mm fibre cement sheet, weatherboards or plank cladding on 90 mm timber or 92 mm steel studs with 13 mm plasterboard inside. From category 2 (Rw 41) every wall in Schedule 2 is masonry or concrete, such as insulated brick veneer or 110 mm concrete brickwork. Category 4 (Rw 52) is two leaves of clay brick, at least 270 mm in total.
- Roofs. A tiled or metal roof with sarking and a 10 mm plasterboard ceiling meets Rw 35. With 50 mm of insulation over the ceiling, Schedule 2 accepts it for Rw 38 and 41. Rw 45 needs acoustically rated plasterboard.
- Floors. A 100 mm concrete slab meets Rw 45, and a 150 mm slab meets Rw 51.
- Entry doors. From category 2, a solid core door at least 45 mm thick with full perimeter acoustically rated seals.
A construction that isn't in Schedule 2 can still be used if it has been tested to the required Rw. That matters most for lightweight clad walls at category 2 and above, where Schedule 2 offers only masonry and concrete.
Which buildings and rooms
QDC MP 4.4 applies to Class 1, 2, 3 and 4 buildings: houses, townhouses, secondary dwellings, units and apartments, boarding houses and short-term accommodation, and a dwelling attached to another kind of building. Relocated buildings are excluded. Business Queensland's guidance is that a major renovation, such as an alteration or addition, must comply for the part of the building it covers. Ask your certifier how they'll apply that to your project.
Within the building the requirements apply to habitable rooms: bedrooms, living and dining rooms, studies and kitchens. Bathrooms, laundries, toilets, hallways, walk-in robes and garages aren't habitable rooms.
Mapped category or a noise assessment
There are two ways to get the category.
- The mapping. Read the category for the property from the state mapping on the SPP IMS, and the council's where it has designated roads. This needs no acoustic report.
- A noise assessment. Schedule 3 lets a suitably qualified person predict the noise level at the building and set the category from that. The assessment gives a category for every habitable room on every storey.
The mapping is drawn for the land, before the building exists, and gives every storey the same category. A site-specific noise assessment models the building itself, so rooms on the far side of the house, shielded by the house, often come out one or more categories lower than the map shows. If there are solid fences or noise barriers as part of the development, the site-specific noise assessment will also consider how these reduce the category for each room.
What QDC MP 4.4 doesn't cover
- Aircraft noise. A Queensland site inside an airport's ANEF 20 contour is assessed separately under AS 2021. See What is AS 2021?
- Roads and railways that aren't designated, however busy.
- Buildings outside Classes 1 to 4, such as offices, shops and schools.
- Outdoor living areas such as backyards and balconies.
- Noise conditions on a development approval. A planning approval can include noise requirements as conditions, which are separate from MP 4.4.
The noise reductions in Schedule 1 assume the windows and doors are closed, so it's worth planning how those rooms will be ventilated and cooled with the windows shut.
The mapping changes
TMR updates the corridor mapping from time to time, and in mid-2026 it consulted on a remodel of the state-controlled road corridors. Check the current mapping when you apply for building approval, not the mapping from when you bought the land.
Sources
- Queensland Government, Queensland Development Code MP 4.4 Buildings in a transport noise corridor, version 1.1, 17 August 2015, Schedules 1 to 3. Available from Business Queensland.
- Business Queensland, Transport noise corridors.
- Building Act 1975 (Qld), Chapter 8B.
- Department of Transport and Main Roads, Transport Noise Management Code of Practice, Volume 1: Road Traffic Noise, 2013, chapter 8.
- Queensland Government, Building and Plumbing Newsflash 499 (Logan), 566 (Redland) and 639 (2026 consultation on state-controlled road corridors).